• Product Overview

  • Product Details

  • Data Download

  • Related Products

GW9 Outdoor Isolation Switch

Picture
Video
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch Featured Image
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
  • GW9 Outdoor Isolation Switch
S9-M Oil-immersed  Transformer

GW9 Outdoor Isolation Switch

The”GW9-10G” of outdoor MV isolator switch is the high voltage switch equipment of single phase AC50Hz.The product is suitable for power system with rated voltage 10KV to make or break power supply under circumstances of with voltage and nomload.
The isolator adopts isolated rod to operate.
Standard:IEC 60129

Conatct Us

Product Details

Selection

product description01

Operating conditions

1. The altitude does not exceed 1000m.
2. The ambien t air temperature: Maximum+40℃: Minimum: General Area-30℃, Paramos-40℃ .
3. The wind pressure does not exceed 700Pa.
4. The earthquake intensity does not exceed 8 degrees.
5. The working situation without frequent violent vibration.
6. The installation site of ordinary type isolator s hould be kept away from gas,smoke chemical deposition, salt-spray-fog, dust and other and corrosive maters that affect seriously insulation and conuction capability of the isolator.
7. Pollution-proof type isolator is applies to severe filthy conduction area, however,
8. It shouldn’t be any explosive matters and matters causing fire.

product description02

Technical data

Item Unit Value
Technical data KV 10 15 24
Rated working voltage KV 12 17.5
Rated insulation level 1min power frequency withstand voltage (effective value) to ground KV 42 55 65
Fracture KV 48 65 79
Lightning impulse withstand voltage (peak) to ground KV 75 105 125
Fracture KV 85 120 145
Rated frequency HZ 50
Rated current A 200 400 630 1250 400 630
4s short-time withstand current KA 6.3 12.5 20 31.5 16 20
Rated peak withstand current KA 16 31.5 50 80 40 50
Creepage distance mm 300 380
Mechanical life Time 2000 2000 2000

Overall and mounting dimensions(mm)

product description03