• Product Overview

  • Product Details

  • Data Download

  • Related Products

JXF Low-voltage Integrated Distribution Box

Picture
Video
  • JXF Low-voltage Integrated Distribution Box Featured Image
  • JXF Low-voltage Integrated Distribution Box Featured Image
  • JXF Low-voltage Integrated Distribution Box Featured Image
  • JXF Low-voltage Integrated Distribution Box Featured Image
  • JXF Low-voltage Integrated Distribution Box Featured Image
  • JXF Low-voltage Integrated Distribution Box
  • JXF Low-voltage Integrated Distribution Box
  • JXF Low-voltage Integrated Distribution Box
  • JXF Low-voltage Integrated Distribution Box
  • JXF Low-voltage Integrated Distribution Box
S9-M Oil-immersed  Transformer

JXF Low-voltage Integrated Distribution Box

Application: mainly applicable in places with high automation and need to communicate with computer, like large power station and petrochemistry system, as the low voltage distribution device of the distribution and motor controlling, and reactive power compensation in power system.
Protection degree IP30, IP40. Bus type: three phase four wires, three phase five wires. Operation type: in-place, long-distance and automatic
Standard: IEC60439-1

Conatct Us

Product Details

Selection

product-description1

Operating conditions

1. Installation Site: Indoor or outdoor;
2. Atitude: No more than 2000m.
3. Earthquake lntensity: No more than 8 degrees.
4. Ambient Temperature: No more than +40℃ and no less than -25℃.Averagetemperature is no more than +35℃ within 24 hours.
5. Relative Humidity: the average daily value is no more than 95%, the averagemonthly value is no more than 90%.
6. Installation locations: without fire,explosion danger,serious pollution,chemical corrosion and violent vibration.

Features

1.Harmonious and beautiful color matching.
2.Standardized design, compact structure,strong versatility
3.The size of the box can be changed according to the demand .
4.The electric mounting plate can be detachable separately.
5.It has dozens of single line scheme numbers or derivative scheme numbersfor choice and wide range of application.

Technical data

No. Content Unit Value
1 Rated operating voltage V 380
2 Rated lnsulation voltage V 500
3 Raled Frequency Hz 50/60
4 Max Operation Current A ≤250
5 Frequency Withstand Voltage in 1min of Aux Control Loop kV 1.89
6 Rated lmpulse Withstand voltage kV 2.5
7 Protection degree IP Ip30
8 Electrical Clearance mm ≥3
9 Creepage Distance mm ≥10

*: Sizes are customized as needed