FN AC Summus intentione Lond SWITCH
Electio data technica Rated voltage(kV) Summa intentionis (kV) Rated current(A) Industrialis frequentia intentionis resistendi in 1min(kV) 4S thermarum stabilium currentis (valoris efficax) (A) 12 12 400 42/48 12.5 12 12 630 42/ 48 20 Stabilis vena activa (cacumen valor) (A) Brevis circuitio proxima currentis (A) Ratum current apertum (A) Ratum translatio currentis (A) 31.5 31.5 400 1000 50 50 630 1000 Type Plena type DS Earthing switch at inlet position DX Earthing switch ad diverticulum positionis L Interlock...S9-M Oleum immersum Transformer
Electio operans condiciones temperatus ambiens: temperatura maxima: +40°C, temperatura minima: -25℃. Mediocris caliditas mensis calidissimi: +30℃, mediocris temperatus in anno calidissimo: +20℃. Altitudo 1000m non excedens. The waveform of the power supply voltage is similar to a sine wave. Tres phases copia intentionis proxime symmetriarum debet esse. Totum harmonicum onus currentis non excedunt 5% currentis aestimati. Ubi uti: intus vel foris. Featu...ZW32-24 Outdoor Vacuum Circuit Breaker
Electio operans condiciones 1. Ambiens temperies aeris: Cotidiana temperatus variatio: -40℃ ~+40℃ Variatio diurnae temperaturae minus quam 25℃; 2. Altitudo: non plus quam 2000 metra 3. Celeritas venti non plus quam 35m/s est (aequivalens 700Pa in superficie cylindrici); 4. Glacies operimento crassitudine non plus quam 10 mm; 5. Intensio solis non plus quam 1000W/m ² 6. Pollutionis gradus non plus quam GB 5582 IV classis 7. Intensio seismica non excedit 8 classis 8. Nulla flammabilis, explosi...FZN25/FZRN25-12 Indoor Vacuum Load Switch
Electio condiciones operativas 1. Ambiens temperies aeris: terminus superior +40℃, terminus inferior -25℃ (permitte repono ad – 30℃), mediocris valor 24h non altior quam +35℃; 2. Altitude: non plus quam 1000m; III. Relativum humiditas: cotidie mediocris valor non est maior quam 95%, menstrua mediocris non est maior quam 90%; 4. Terrae motus intensio: non excedunt VIII gradus; 5. Aer ambiens non est gas mordax et flammabilis, vapor et alia pollutio significantia; 6. nulla iusto tremore vehemens; 7. Cont.ZN63(VS1)-12S Indoor Vacuum Circuit Breaker (P.
Electio ZN63(VS1) - 12 PT 630 - 25 HT P210 Nomen Ratum voltage(KV) Poli genus mechanismi Operating Rated current(A) Rated breve spatium currentis fractionis (KA) Installation Phase spacing Indoor vacuum circuit ruptor 12:12KV P: Solidum - typum T: Ver genus 630, 1250, 1600, 2000, 2500, 3150, 4000 20, 25, 31.5, 40 HT: Handcart FT: genus certum P150, P210, P275 Nota: ZN63(VS1)-12P duplicem adoptat. ver mechanismum integratum per defaltam. Si unum ver...GW9 Outdoor Isolation Switch
Electio condiciones operans 1. Altitudo 1000m non excedit. 2. Ambien t aeris temperies: Maximum+40℃: Minimum: Area Generalis-30℃, Paramos-40℃ . 3. Ventorum pressio 700Pa non excedit. 4. Terre motus intensio non excedit VIII gradus. 5. Locus laborantis sine frequenti tremore vehementi. 6. Situs institutionis ordinariae generis isolatoris prohibendus est a gas, fumo chemico depositionis, salinarum nebulae, pulveris aliorumque et mordorum maternorum quae gravia afficiunt...