XRNP kuchlanishni o'tkazish uchun oqim cheklovchi sigortalar...
Tanlash Texnik ma'lumotlar Turi Nominal kuchlanish (Kv) Nominal oqim (A) Nominal uzilish oqimi (KA) O'lchamlar XRNP1- □/□-□-1 7,2 (3,6) 12 0,2,0,3,0,5,1,2,3,150-rasmga qarang. XRNP1- □/□-□-1 24 0,2,0,3,0,5,1,2,3,15 50 2-rasmga qarang XRNP1- □/□-□-2 12 2,3,15 X-□-6-rasmga qarang. 1 40,5 0,2,0,3,0,5,1,2,3,15 31,5 4-rasmga qarang( PH25 ) XRNP6- □/□-□-3 0,2,0,3,0,5,5,5,3-rasmga qarang 0 ) XRNP6- □/□-□-4 0,2/0,5/1/2/3,15/5/6,3 6-rasmga qarang ( PH41 ) Eslatma: 7....RN1 ichki oqimni cheklovchi sug'urta
Xususiyatlari Belgilangan elektr tokidan 1,3 baravar ko'p bo'lganda sug'urtadan o'tadigan oqim,Bir soat davomida eritib yubormang; Sug'urta orqali o'tadigan oqim o'zining maxsus elektr tokidan 2 baravar ko'p bo'lsa, bir soat ichida eritiladi; Sug'urtani tanlashda uning 1-chizmadagi termoyadroviy xususiyati egri chizig'iga qarang. 1-rasm RN1/RN3“Bir soniya” xarakteristikasi egri chizig'i Texnik ma'lumotlar 3 6 10 35 Nominal tok (A) 20 100 200 300 400 200 75 100 200 300 20 50 75 107 200 va maksimal burilish 200 KV e 40 1.3...Dvigatelni himoya qilish uchun XRNM1 oqim cheklovchi sigortalar
Tanlash Texnik ma'lumotlar Nominal kuchlanish (Kv) Nominal uzilish oqimi KA Sug'urtaning nominal oqimi (A) Sug'urta liniyasining nominal oqimi (A) Asosiy o'lchamlar ABCD XRNM1-3,6 3,6 50 125 50,63,100,125 337(390)314)235) (340) 51 200 125,160,200 76 400 250,315,355,400 XRNM1-7,2 7,2 12 160 25,31,5,40,50,63,80,100,43,80,100) (461) 454(150) 76 315 200,224,250,315 Izoh: 1. Yuqorida keltirilgan nominal parametrlar bitta quvur, sigortalar joyida parallel ravishda ulanishi mumkin ...Transformer Pro uchun XRNT oqim cheklovchi sigortalar...
Tanlash Texnik ma'lumotlar Turi Nominal kuchlanish Sug'urtaning nominal oqimi (A) Sigortaning nominal oqimi (A) XRNT-12 12 40 3.15, 6.3, 10, 16, 20, 25, 31,5, 40 XRNT-1200 151 、71、80、100、(125) XRNT-12 12 125 125、160、200、250 XRNT-24 24 200 3,15、6,3、10、120、25、3405 、63, 80, 100 、125, 160, 200 XRNT–40,5 40,5 125 3,15, 6,3, 10, 16, 20, 25, 31,5, 40, 50, 63, 80, 2 va 12 dan ortiq o'lchamlari (mm) Chat1/a havola XRNT-12Kv Chat2/a li...PRW1 sug'urtasi
Tanlash Ishlash shartlari 1. Yuqori chegarasi 40 ℃ va pastki chegarasi -30 ℃ bo'lgan muhitlar uchun javob beradi. 2. Balandligi 1000 m dan oshmaydigan, shamol tezligi 35 m/s dan oshmaydigan 3. Sigortalar quyidagi joylarga mos kelmaydi 3.1 Yoqilg'i yoki portlash xavfi bo'lgan joylar. 3.2 Kuchli tebranish yoki zarba bo'lgan joylar. 3.3 G'ayritabiiy elektrokimyoviy gaz ta'siri va havoning kuchli ifloslanishi va tutuni bo'lgan hududlar Chinni korpusli sug'urtaning texnik ma'lumotlari parametri Turi Nominal kuchlanish (kV) Nominal oqim ...