Product Overview
Product Details
Data Download
Related Products
The YVF-12GD series three-position combined vacuum circuit breaker adopts a modular framework structure, integrating vacuum circuit breaker, isolation switch, grounding switch, interlocking mechanism, and operating mechanism, with excellent electrical and mechanical performance.
Mainly used in three-phase AC 50HZ power systems with a rated voltage of 3.6KV-12KV, for control and protection purposes in industrial and mining enterprises, power plants, and substations. It is a new generation of high-performance miniaturized medium voltage electrical products.
Standard: IEC 62271-100
Conatct Us
Note:
If there is no grounding switch, the grounding operation shaft acts as an interlocking shaft, and the external dimensions remain unchanged.
● Ambient temperature: -25℃ +40℃;
● Relative humidity: daily average <95%, monthly average <90%;
● Altitude: not higher than 1000m;
● Earthquake intensity: no more than 8 degrees:
● Place of use: No explosion hazard, chemical and severe vibration and pollution.
● Service conditions above an altitude of 1000 meters
● When the altitude exceeds 1000 meters,the air density will decrease relatively, which will affect the protection factor of electrical appliances.
● Safe and excellent solid-sealed pole
High reliability, stable insulation performance, stronger structure, miniaturization, maintenance-free, more environmentally friendly, high mechanical resistance
● Visual isolation fracture
Rotary isolation switch with visible fracture after opening
● Modular operating mechanism
The circuit breaker adopts a modular operating mechanism, which can be independently replaced or repaired, and has good interchangeability. It can be manually operated, as well as AC and DC energy storage operations to achieve remote control
● Three-axis step-by-step operation, reliable mechanical interlock
The isolation switch, circuit breaker, and grounding switch are operated separately on one axis, and there is a forced mechanical interlocking between the three axes to prevent misoperation
● Outgoing terminal with non-contact live display sensor
No capacitance, non-contact induction technology, safe and reliable
● Cabinet door and connecting switch are designed with reliable interlocking structure
Ensure operator safety with adjustment-free cabinet door latching
Item | Unit | Parameter | ||
Rated voltage | kV | 12 | ||
(1min) Rated short-time power frequency withstand voltage: phase to phase/break | 42/48 | |||
Rated lightning impulse withstand voltage(peak): phase-to-phase/break | 75/85 | |||
Secondary circuit power frequency withstand voltage (1min) | V | 2000 | ||
Rated frequency | Hz | 50 | ||
Rated current | A | 630,1250 | ||
Rated short-circuit breaking current | kA | 20 | 25 | 20 |
Rated peak withstand current | kA | 50 | 63 | 50 |
Rated short-circuit making current | kA | 50 | 63 | 50 |
4s rated short-time withstand current | kA | 20 | 25 | 20 |
Rated short-time withstand current duration | S | 4 | ||
Rated single/back to back capacitor bank breaking current | A | 630/400 | ||
Rated capacitor bank making inrush current | kA | 12.5(HZ≤1000Hz) | ||
Rated short-circuit current breaking times | Times | 30 | ||
Mechanical life (isolation switch/circuit breaker/grounding switch) | 3000/10000/3000 | |||
The accumulative thickness of allowable wear of moving and static contacts | mm | 3 | ||
Rated closing operating voltage | V | AC24/48/110/220 DC24/48/110/220 | ||
Rated opening operating voltage | ||||
Rated voltage of energy storage motor | V | AC24/48/110/220 DC24/48/110/220 | ||
Rated power of energy storage motor | W | 70 | ||
Energy storage time | S | ≤15 | ||
Contact distance | mm | 9±1 | ||
Overtravel | 3.5±1 | |||
Contact closing bounce time | ms | <5 | ||
Three-phase opening and closing asynchronous | ≤2 | |||
Opening time (rated voltage) | ≤40 | |||
Closing time (rated voltage) | ≤60 | |||
Average opening speed (contact just opened ~ 6mm) | m/s | 0.9~1.3 | ||
Average closing speed (6mm~ contact just closed) | 0.4-0.8 | |||
Contact opening rebound amplitude | mm | ≤2 | ||
Contact closing contact pressure | N | 2400±200( 20-25kA) 3100+200(31.5kA) | ||
Rated operating sequence | O-0.3s-CO-180s-CO |
Standard configuration: Wiring according to the standard wiring diagram, including anti-tripping device, no locking device, no over- current device, no under-voltage device
Item | Parameter | Note |
Energy storage motor | 75W | Standard |
Closing coil | A(D)C24~220V | Standard |
Opening coil | A(D)C24~220V | Standard |
Isolation switch auxiliary switch | 1Open1Close5A | Standard |
Grounding switch auxiliary switch | 1Open1Close5A | Standard |
Energy storage mechanism auxiliary switch | 2Open1Close5A | Standard |
Circuit breaker auxiliary Switch | 8Open8Close5A | Standard |
Anti-trip device | A(D)C24~220V | Standard |
Live sensor (inductive) | Non-contact | Standard |
Locking device | A(D)C24~220V | Optional |
Overcurrent release | 3.5A、 5A | Optional |
Undervoltage device | A(D)C24~220V | Optional |
It can be assembled in small fixed cabinets, ring network cabinets or box transformers. The main circuit of VYF-12GD series three- position combined vacuum circuit breaker is arranged longitudinally. The upper part is an isolation switch, the middle part is a vacuum circuit breaker, and the lower part is a grounding switch. Detector mechanism, interlocking mechanism 1 are positioned at switch front, and this switch can be installed upside down.
Dual interlocking: circuit breakers, isolation switches, and grounding switches are equipped with forced mechanical interlocking operations;
Design antimisoperation locking devices for circuit breakers, isolation switches, and grounding switches;
The isolation switch and grounding switch are operated separately on an independent shaft in steps, and a forced mechanical interlocking operation is set between the two operations;
After the switch opening and closing operation, please observe and confirm their respective opening and closing states.
Formal overall dimensions
Formal overall dimensions