ZN23-40.5 Indoor Vacuum Circuit Breaker

Picture
Video
  • ZN23-40.5 Indoor Vacuum Circuit Breaker Featured Image
  • ZN23-40.5 Indoor Vacuum Circuit Breaker Featured Image
  • ZN23-40.5 Indoor Vacuum Circuit Breaker Featured Image
  • ZN23-40.5 Indoor Vacuum Circuit Breaker Featured Image
  • ZN23-40.5 Indoor Vacuum Circuit Breaker Featured Image
  • ZN23-40.5 Indoor Vacuum Circuit Breaker Featured Image
  • ZN23-40.5 Indoor Vacuum Circuit Breaker
  • ZN23-40.5 Indoor Vacuum Circuit Breaker
  • ZN23-40.5 Indoor Vacuum Circuit Breaker
  • ZN23-40.5 Indoor Vacuum Circuit Breaker
  • ZN23-40.5 Indoor Vacuum Circuit Breaker
  • ZN23-40.5 Indoor Vacuum Circuit Breaker
S9-M Oil-immersed  Transformer

ZN23-40.5 Indoor Vacuum Circuit Breaker

ZN23-40.5 MV vacuum circuit breaker is indoor MV distribution device of three-phase AC 50Hz, rated voltage 40.5kV, can be matched with JYN35/GBC-35 type  switch  cabinet.  Suitable for  control  and  protection  in  power  plant,  substation  and  power distribution system, especially suitable for frequent operation places. The vacuum circuit breaker is handcart type, with reasonable structure, convenient maintenance, safe and reliable use.

Conatct Us

Product Details

Selection

product description01

Operating conditions

1. The environment temperature: upper limit +40℃, lower limit -15℃ (cold area -25℃);
2. Altitude: not more than 2000m;
3. Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%;
4. Saturated steam pressure: daily average value is not higher than 2.2 × 10 -3 Mpa,monthly average is not higher than 1.8×10-3 Mpa;
5. Earthquake intensity does not exceed 8 degrees;
6. No fire, explosion, pollution, chemical corrosion and severe vibration place.

Features

1. The overall structure of circuit breaker is handcart type, use CT19 or CD10 mechanism, can be divided into JYN1 and GBC two kinds of structure.
2. The circuit breaker body is composed of frame, insulator, vacuum interrupter, spindle and moving and static bracket. The bottom surface of the frame is equipped with 4 wheels, for moving circuit breaker, etc. the right side of the frame is equipped with 6 insulator as support, fixed moving and static support use, vacuum interrupter installed between the dynamic, static support, the circuit breaker has the characteristics of small volume, simple structure, long service life, easy maintenance, no explosion danger, no pollution etc.

Principle of operation

The circuit breaker is equipped with middle sealing longitudinal magnetic field vacuum interrupter, when the dynamic, static contact of vacuum interrupter is separated charged, contact gap will produce vacuum arc and extinguished when the current over zero. Due to the special structure of contact, the contact gap will produce appropriate longitudinal magnetic field during contact arc, the arc uniformly distributed on the surface of the contact, maintaining a low arc voltage, so that less electric corrosion speed and the arc chamber  with  high  arc  media  recovery  strength,  improve  the  circuit  breaker  breaking  short-circuit  current  capability  and  life electrical.

Technical data

Item Unit Parameter
Parameters of voltage, current, life
Rated voltage kV 40.5
Rated short time power frequency withstand voltage (1min) kV 95
Rated lightning impulse withstand voltage (peak) kV 185
Rated frequency Hz 50
Rated current A 1250                                 1600                                   2000
Rated short-circuit breaking current kA 25 31.5
Rated short-time withstand current (RMS) kA 25 31.5
Rated peak withstand current kA 63 80
Rated short-circuit closing current kA 63 80
Rated single / back-to-back capacitor bank breaking current A 600/400
Rated short-circuit current duration S 4
Rated short-circuit current breaking times Times 20
Rated operating sequence O-0.3s-CO-180s-CO
The main galvanic circle resistance μΩ ≤65
Rated operation voltage ≌ 220/110
Mechanical life Times ≥10000
Mechanical property parameters
Open clearance between contacts mm 22±2
Overtravel mm 6±1
Contact closing bounce time ms ≤3
Three-phase, switching synchronism ms ≤2
Average opening speed m/s 1.7±0.2
Average closing speed m/s 0.75±0.2
Opening time (rated voltage) ms ≤90
Closing time (rated voltage) ms ≤60
Allowable wear thickness for dynamic and static contact mm 3

Overall and mounting dimensions(mm)

product description02

Data Download

  • ico_pdf

    ZN23-40.5 Indoor Vacuum Circuit Breaker

Related Products